IPP Software Navigation Tools IPP Links Communication Pan-STARRS Links

Changes between Version 10 and Version 11 of Kron_measurements_investigation


Ignore:
Timestamp:
May 22, 2012, 10:31:35 AM (14 years ago)
Author:
bills
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • Kron_measurements_investigation

    v10 v11  
    1313   * No Window no weight, no smooth
    1414 * Results
     15
     16== Overview ==
     17On April 12 Peter Draper pointed out that the Kron radii measured by psphot using the default recipe are much lower than those
     18measured by SExtractor. He found that if the gaussian weighting function is removed, more sensible results are obtained. 
     19See plot at http://ps1sc.ifa.hawaii.edu/PS1wiki/index.php/KP12videocon_page#Kron_radii_-_possible_improvement
     20
     21Using a set of 40 simulated images provided by Peter we have done many experiments with psphot to invesigate
     22the accuracy of the kron measurements. We reported April 30 at the DRAVG
     23meeting that results closer to SEXtractor can be achieved with a prototype version of psphot which
     24smooths the input image with a 1.7 pixel gaussian prior to measuring the kron radius and flux.
     25http://ps1sc.ifa.hawaii.edu/PS1wiki/index.php/DRAVG_telecon#Kron_radii_improvements
     26
     27We have more carefully implemented the smoothing function and the code is now included in the ipp-trunk.
     28
     29There are several recipe values that now may be used to control the psphot kron measurements
     30
     31
     32
     33
    1534
    1635== Results ==