    1717  * ipp001,ipp003 need mysql shutdown cleanly before halting the machines
    1818  * power off all machines once halted -- Gavin fixed remote power management on ippb04,b05
     19  * nominal Temp to monitor --
     20{{{
     21-- ipp002 --
     22Core0 Temp:
     23             +44 C
     24Core1 Temp:
     25             +47 C
     26temp1:       +41 C  (high =    +4 C, hyst =   +16 C)   sensor = thermistor   ALARM   
     27temp2:     +43.5 C  (high =   +80 C, hyst =   +75 C)   sensor = thermistor           
     28temp3:     +43.0 C  (high =   +80 C, hyst =   +75 C)   sensor = thermistor         
     29
     30-- ippops1 --
     31temp1:       +36.8 C  (high = +100.0 C, hyst = +95.0 C)  sensor = Intel PECI
     32temp2:      -128.0 C  (high = +100.0 C, hyst = +95.0 C)  sensor = thermal diode
     33temp5:       +40.0 C  (high = +100.0 C, hyst = +95.0 C)  sensor = thermistor
     34temp6:       +41.0 C  (high = +100.0 C, hyst = +95.0 C)  sensor = thermistor
     35
     36-- ippops2 --
     37temp1:       +35.8 C  (high = +100.0 C, hyst = +95.0 C)  sensor = Intel PECI
     38temp2:      -128.0 C  (high = +100.0 C, hyst = +95.0 C)  sensor = thermal diode
     39temp5:       +39.0 C  (high = +100.0 C, hyst = +95.0 C)  sensor = thermistor
     40temp6:       +40.0 C  (high = +100.0 C, hyst = +95.0 C)  sensor = thermistor
     41}}}
     42
    1943 * MEH: ippc121 has been stalling processing @camera stage -- out of normal nightly processing for now
    2044 * 15:45 CZW: Restarted retired host reinsertion as ipptest in screen session on stare02.  The check to confirm hosts can be retired is running slowly, as it is scanning for the existence of all files that have database entries on the retired hosts.  Reinserting will reduce the number of these that need to be checked, and the check can be resumed post-reinsertion at the point it was stopped.  This should have minimal impact, but feel free to control-C if ipp118-ipp122 loads are too high/slows down processing.
     45  * the ones doing this need to monitor the level of nebulous replication slippage (looks like ~1700,3900/hr) and  adjust it accordingly if gets behind during nightly processing
     46 * MEH: Haydn work at ITC
     47  * ipp081 back up again -- leave neb-host down for day or so and then put into repair only until have remote power access
     48  * ipp090,091 rebooted to report number of CPU properly (12 not 24) -- ipp091 raid card is dead, new ones ordered and will arrive in week or two
     49  * ippdb05 needs new BBU -- wait until Monday
     50  * ipp085,086,089 also need BBU but wait until db05 replaced next week
     51 * MEH: ipp116.0 has gpc1 DB replication and <1TB free space.. -- should have been put into repair a while ago...
    2152=== Saturday : YYYY.MM.DD ===