| Version 6 (modified by , 12 years ago) ( diff ) |
|---|
- 2009-09-19T16:50 many ipp job failures because ipp047 could not access /data/ipp024.0 shutdown and power cycled ipp024 did not help. shutdown and power cycling ipp047 "fixed" the problem
- 2009-09-10T09:35:52 Degraded unit: unit=0, port=15 (replaced)
- Jul 19, 2011 08:47:30PM ERROR - Degraded unit: unit=0, port=5
- 2013-08-22 Motherboard caught fire, fire spread to one power supply between 12:30am and 1am HST.
- 2014-08-14T07:07:47 system unresponsive, nothing on console, power cycled by gavin (2014-08-14T07:16:49)