IPP Software Navigation Tools IPP Links Communication Pan-STARRS Links

Ignore:
Timestamp:
May 10, 2011, 6:47:00 PM (15 years ago)
Author:
eugene
Message:

do not print a message for every failed mag measurement (eg, CR); add MIN SX,SY for psf clump

File:
1 edited

Legend:

Unmodified
Added
Removed
  • branches/eam_branches/ipp-20110505/psphot/src/psphotRoughClass.c

    r31452 r31522  
    180180            psAssert (status, "missing MOMENTS_SY_MAX");
    181181        }
    182 
    183         psfClump = pmSourcePSFClump (NULL, region, sources, PSF_SN_LIM, PSF_CLUMP_GRID_SCALE, MOMENTS_SX_MAX, MOMENTS_SY_MAX, MOMENTS_AR_MAX);
     182        float MOMENTS_SX_MIN = psMetadataLookupF32(&status, analysis, "MOMENTS_SX_MIN");
     183        if (!status) {
     184            MOMENTS_SX_MIN = psMetadataLookupF32(&status, recipe, "MOMENTS_SX_MIN");
     185            if (!status) {
     186                MOMENTS_SX_MIN = 0.5;
     187            }
     188        }
     189        float MOMENTS_SY_MIN = psMetadataLookupF32(&status, analysis, "MOMENTS_SY_MIN");
     190        if (!status) {
     191            MOMENTS_SY_MIN = psMetadataLookupF32(&status, recipe, "MOMENTS_SY_MIN");
     192            if (!status) {
     193                MOMENTS_SY_MIN = 0.5;
     194            }
     195        }
     196
     197        psfClump = pmSourcePSFClump (NULL, region, sources, PSF_SN_LIM, PSF_CLUMP_GRID_SCALE, MOMENTS_SX_MAX, MOMENTS_SY_MAX, MOMENTS_SX_MIN, MOMENTS_SY_MIN, MOMENTS_AR_MAX);
    184198
    185199        psMetadataAddF32 (regionMD, PS_LIST_TAIL, "PSF.CLUMP.X",  PS_META_REPLACE, "psf clump center", psfClump.X);
Note: See TracChangeset for help on using the changeset viewer.