Changeset 40270 for trunk/ippToPsps/config/tables.ST.vot
- Timestamp:
- Dec 12, 2017, 10:59:02 AM (9 years ago)
- File:
-
- 1 edited
-
trunk/ippToPsps/config/tables.ST.vot (modified) (7 diffs)
Legend:
- Unmodified
- Added
- Removed
-
trunk/ippToPsps/config/tables.ST.vot
r39268 r40270 93 93 </FIELD> 94 94 <FIELD name="photoZero" arraysize="1" datatype="float" unit="magnitudes" default="-999"> 95 <DESCRIPTION>Locally derived photometric zero point for this stack.</DESCRIPTION> 95 <DESCRIPTION>Locally derived photometric zero point for this stack (PSF-like measurements only).</DESCRIPTION> 96 </FIELD> 97 <FIELD name="photoZeroAperture" arraysize="1" datatype="float" unit="magnitudes" default="-999"> 98 <DESCRIPTION>Locally derived photometric zero point for this stack (Aperture-like measurements only).</DESCRIPTION> 96 99 </FIELD> 97 100 <FIELD name="ctype1" arraysize="100" datatype="char" unit="dimensionless" default=""> … … 587 590 </FIELD> 588 591 <FIELD name="gzp" arraysize="1" datatype="float" unit="magnitudes" default="0"> 589 <DESCRIPTION>Photometric zeropoint for the g filter stack. Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 592 <DESCRIPTION>Photometric zeropoint for the g filter stack (PSF-like magnitudes only). Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 593 </FIELD> 594 <FIELD name="gzpAPER" arraysize="1" datatype="float" unit="magnitudes" default="0"> 595 <DESCRIPTION>Photometric zeropoint for the g filter stack (APERTURE-like magnitudes only). Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 590 596 </FIELD> 591 597 <FIELD name="gPlateScale" arraysize="1" datatype="float" unit="arcsec/pixel" default="0"> … … 694 700 </FIELD> 695 701 <FIELD name="rzp" arraysize="1" datatype="float" unit="magnitudes" default="0"> 696 <DESCRIPTION>Photometric zeropoint for the r filter stack. Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 702 <DESCRIPTION>Photometric zeropoint for the r filter stack (PSF-like magnitudes only). Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 703 </FIELD> 704 <FIELD name="rzpAPER" arraysize="1" datatype="float" unit="magnitudes" default="0"> 705 <DESCRIPTION>Photometric zeropoint for the r filter stack (APERTURE-like magnitudes only). Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 697 706 </FIELD> 698 707 <FIELD name="rPlateScale" arraysize="1" datatype="float" unit="arcsec/pixel" default="0"> … … 801 810 </FIELD> 802 811 <FIELD name="izp" arraysize="1" datatype="float" unit="magnitudes" default="0"> 803 <DESCRIPTION>Photometric zeropoint for the i filter stack. Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 812 <DESCRIPTION>Photometric zeropoint for the i filter stack (PSF-like magnitudes only). Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 813 </FIELD> 814 <FIELD name="izpAPER" arraysize="1" datatype="float" unit="magnitudes" default="0"> 815 <DESCRIPTION>Photometric zeropoint for the i filter stack (APERTURE-like magnitudes only). Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 804 816 </FIELD> 805 817 <FIELD name="iPlateScale" arraysize="1" datatype="float" unit="arcsec/pixel" default="0"> … … 908 920 </FIELD> 909 921 <FIELD name="zzp" arraysize="1" datatype="float" unit="magnitudes" default="0"> 910 <DESCRIPTION>Photometric zeropoint for the z filter stack. Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 922 <DESCRIPTION>Photometric zeropoint for the z filter stack (PSF-like magnitudes only). Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 923 </FIELD> 924 <FIELD name="zzpAPER" arraysize="1" datatype="float" unit="magnitudes" default="0"> 925 <DESCRIPTION>Photometric zeropoint for the z filter stack (APERTURE-like magnitudes only). Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 911 926 </FIELD> 912 927 <FIELD name="zPlateScale" arraysize="1" datatype="float" unit="arcsec/pixel" default="0"> … … 1015 1030 </FIELD> 1016 1031 <FIELD name="yzp" arraysize="1" datatype="float" unit="magnitudes" default="0"> 1017 <DESCRIPTION>Photometric zeropoint for the y filter stack. Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 1032 <DESCRIPTION>Photometric zeropoint for the y filter stack (PSF-like magnitudes only). Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 1033 </FIELD> 1034 <FIELD name="yzpAPER" arraysize="1" datatype="float" unit="magnitudes" default="0"> 1035 <DESCRIPTION>Photometric zeropoint for the y filter stack (APERTURE-like magnitudes only). Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 1018 1036 </FIELD> 1019 1037 <FIELD name="yPlateScale" arraysize="1" datatype="float" unit="arcsec/pixel" default="0"> … … 4790 4808 </FIELD> 4791 4809 <FIELD name="zp" arraysize="1" datatype="float" unit="magnitudes" default="0"> 4792 <DESCRIPTION>Photometric zeropoint . Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION>4810 <DESCRIPTION>Photometric zeropoint of frame/exposure. Necessary for converting listed fluxes and magnitudes back to measured ADU counts.</DESCRIPTION> 4793 4811 </FIELD> 4794 4812 <FIELD name="expTime" arraysize="1" datatype="float" unit="seconds" default="-999">
Note:
See TracChangeset
for help on using the changeset viewer.
