| Version 3 (modified by , 13 years ago) ( diff ) |
|---|
Summary of MOPS_depthloss_test130715
MOPS has noted often in the past of signal-to-noise issues (primarily not reaching the detection depths expecting and varying signal-to-noise measures). This has been traced back to an incorrect propagation of the covariance in the difference images.
Alan suggested a couple of chunks for comparison testing with a more appropriate covariance propagation (at least for all but the brightest sources)
- TJD 56065, chunk 152.OSS.D.Q.w as a night where can compare with both the original diffim photometry and also the chip-level photometry (20120518)
- TJD 56477, chunk 166.OSS.J.Q.w for a very recently observed set (20130704)
Reprocessing details -- started on 20130715
- gpc1db warp label, data_group -- meh_mopstestoss130715_nodualwav, OSS.20120518 and OSS.20120704 (unchanged)
- gpc1db diff label, data_group -- meh_mopstestoss130715_nodualwav, OSS.20120518 and OSS.20120704 (unchanged)
- gpc1db publishing label -- meh_mopstestoss130715_nodualwav
- gpc1db publish_id range: 833334--833411 (all inclusive)
- datastore time registered starting 2013-07-17T00:45:16Z
It is important to note that these reprocessed diffims also included the dual convolution option also turned off (though only a small % wanted dual as seen from the original processing)
More will be added to this page as time allows.
Related summary pages:
- MOPS_IASC20130319_tests130422 -- has been key page for setting up examples and identifying problems
- MD_WSdiffim_photcheck_test20121004
- ppSub_testing_201201
- MOPS_diff_false_positives